DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-299BRI-BD/LGATE-BD (ISDN-BRI Line Circuit Pack)
9
Notes:
a. This error indicates the circuit pack totally stopped functioning or it was
physically removed from the system.
NOTE:
The alarm is logged approximately 11 minutes after the circuit pack
has been removed and/or SAKI Sanity Test (#53) fails.
If the circuit pack is not in the system, insert a circuit pack (in the same
slot as the error indicates) to resolve this error. Or, if the circuit pack is in
the system and the red LED is on, then follow the instructions for ‘‘Red
(alarm)’’ in Chapter 7, ‘‘LED Interpretation’’
.
b. This circuit pack has been busied out via the busyout board UUCSS
command.
c. Port(s) has(have) been administered on this circuit pack but the circuit
pack is not physically present.
d. This error indicates transient communication problems between the switch
and this circuit pack. Execute the test board UUCSS command and refer
to the repair procedures for the Control Channel Loop Around Test (#52).
1793 (j) 46080 MINOR ON
1794 (j) 46094 MINOR ON
1795 (j) 46085 MINOR ON
2306 (j) LANBIC Receive
Parity Error Counter
Test (#595)
3330 (k) 46083 MINOR OFF
3840 (l) 4096
to
4101
3843 (m) 46097
3999 (n) Any None
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Table 9-136. BRI-BD Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page