
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-457DAT-LINE (Data Line Port)
9
9
DAT-LINE (Data Line Port)
The TN726 Data Line circuit pack has 8 ports, each of which supports an RS-232
interface to asynchronous Customer Premises Equipment (CPE). Each of these
ports and the equipment connected to it constitute a data line. For DT-LN-BD
(Data Line Circuit Pack) errors, refer to "XXX-BD (Common Port Circuit Pack)".
Check circuit pack-level errors first since the usability of the ports depend on the
health of the circuit pack.
Data line ports are administered at the terminal with the
add data-module
command. The data module type is
data-line
. The
list data-module
command
will list all administered data modules in the system. See “PDATA-PT” for details
on how data lines are used as system ports.
The TN750 Announcement circuit pack also has one data line-type port on it.
This data line port is used for saving and restoring announcements. For a
description of this feature and repair instructions for the TN750, refer to
“ANN-BD”.
NOTE:
If the tests for the data line port in question pass, and user-reported
complaints persist, there is probably an external problem. Test the
asynchronous data unit (ADU), following the procedures outlined in
User
Manual Z3A Asynchronous Data Unit
, 555-401-701. If the ADU appears to
be working properly, check the external wiring, and then check the
customer equipment.
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run
1
1. UU is the universal cabinet number (1 for PPN, 2 -44 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack
resides (01 to 21). pp is the two digit port number (01, 02, ...).
Full Name of
MO
DAT-LINE MINOR test port UUCSSpp l Data Line Port
DAT-LINE WARNING test port UUCSSpp l Data Line Port