DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-743E-DIG-BD (Multi Application Platform Board)
9
9
E-DIG-BD (Multi Application
Platform Board)
The maintenance strategy for DIG800-BD is the same as the one described for
MO-COMBD (MO-XXX-BD). Maintenance testing of the common circuit pack is
handled by on-board firmware and SPE controlled tests. Maintenance software
queries the firmware for error and alarm information, status, and test results. The
firmware automatically reports error conditions that will result in SPE-controlled
testing.
Board Insertion
The switch makes an additional board query if any of the following circuit packs
are inserted:
For any of the above initial board up-links, the switch sends queries requesting
additional data from the board for administration purposes, while also telling the
board the switch software release and the system type.
For the native mode, the response to the board query downlink messages
consists of several CCMS uplink messages that identify the true board code,
vintage, suffix, emulation type, and the number of reserved slots it needs.
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run
1
1. Where UU is the universal cabinet number (1 for PPN and 2-44 for EPN); C is the carrier
designation (for example, A, B, C, D, or E); SS is the address of the slot in the carrier where
the circuit pack is located (for example, 01, 02, ...); and pp is the two digit port number (01,
02, 03, ...).
Full Name of MO
DIG800-BD MIN test board UUCSS sh MO800DIG-BD
DIG800-BD WRN test board UUCSS sh MO800DIG-BD
Circuit Pack Vintage
TN754 49
TN556 49,
80 or greater
TN800 any