DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-163ATM-DCH (ATM D-Channel Port)
9
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. Error Type 18: D-channel busied out; no calls possible over this
D-channel.
b. Error Type 130: circuit pack removed or has been insane for more than 11
minutes. To clear the error, reinsert or replace the circuit pack.
c. Error Type 1793: ATM Trunk circuit pack failed the Signaling Link Board
Check (#643). Resolve any ATM-TRK errors in the Error Log.
Table 9-69. ATM D-channel Error Log entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test port UUCSSpp
2
2. pp is for ports 9-32.
18 (a) 0 busyout port
UUCSSpp
WARNING OFF release port UUCSSpp
130 (b) None WARNING ON test port UUCSSpp
1793 (c) Signaling Link Board
Check (#643)
test board UUCSS l
Continued on next page