DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1758TIE-TRK (Analog Tie Trunk)
9
257(j) 57474 None WARNING OFF
257(k) 57475 None WARNING OFF
513(l) Any EPF M and E Lead
(#74)
MAJ/MIN/
WRN
2
OFF test port
UUCSSpp
sh r 3
769(l) 57481 EPF M and E Lead
(#74)
MAJ/MIN/
WRN
2
ON test port
UUCSSpp
sh r 3
1025(m) Any None MAJ/MIN/
WRN
2
OFF
1281(l) Any EPF M and E Lead
(#74)
MAJ/MIN/
WRN
2
ON test port
UUCSSpp
sh r 3
1537 Looparound and
Conference (#33)
MAJ/MIN/
WRN
2
ON test port
UUCSSpp
l r 3
1793 Tie Trunk Seizure
(#73) (Dial Test #747
for TN439)
MAJ/MIN/
WRN
2
OFF test port
UUCSSpp
sh r 2
2049 NPE Crosstalk (#6) MAJ/MIN/
WRN
2
ON test port
UUCSSpp
l r 3
2305(n) 57424
50944
None (l)
2561(o) 0 None WARNING OFF
2562(p) 16665
2817(o) 0 None MINOR OFF
2817(q) 52992
3073(o) 0 None
3840(r) 8000 Transmission Tests
(ATMS)(#844-848)
OFF test analog-testcall
3841(r) Transmission Tests
(ATMS)(#844-848)
MINOR OFF test analog-testcall
UUCSSpp r 2
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
2. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set
options command. If the MINOR alarm is not downgraded by the set options values, then the MINOR
alarm will be upgraded to a MAJOR alarm if 75% of the trunks in this trunk group are alarmed. These errors,
if applicable, always log a MINOR alarm for TN439 and TN497.
Table 9-658. TIE Trunk Error Log Entries — Continued
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
Continued on next page