A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Initialization and Recovery
4-3Hot Restart
4
4. Use the
save translations
command to make the changes permanent.
!
CAUTION:
To avoid potential loss of servce, ensure that your system’s
translations are protected by saving them to the PCM/CIA card.
Hot Restart
This reset occurs only on a duplicated SPE during a
planned
SPE interchange.
Reset Level 1 (Warm Restart)
Duration Up to 1.5 minutes
Causes
reset system interchange
command
(use of the
contention-override
or
health-override
options
causes a reset level 1 or higher)
SPE interchange requested by scheduled maintenance
Effects Call service is unaffected.
Yellow LEDs light on new active SPE and go out on the new
standby.
Memory shadowing is turned off.
Remote access port (SYSAM-RMT) login is dropped.
Duration Up to 10 seconds, typically 2 seconds
Causes
reset system 1
command
Spontaneous SPE interchange (those caused by hardware
faults)
Software faults that are non-service affecting
Abort of planned SPE interchange
Hardware bus errors
TN1655 Packet Interface faults