DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-42busyout journal-printer
8
Parameters
Examples
For more information see the following sections at the beginning of this chapter:
Busyout
and
Release
Commands, Common Input Parameters, and Common
Output Fields.
busyout journal-printer
busyout journal-printer pms-log | wakeup-log
The
busyout journal-printer
command puts the link to the Property
Management System log or wakeup log printers in a maintenance busy state.
(See Busyout and Release Commands at the beginning of this chapter). When
busied out, the link is dropped and no data transfer can take place over it.
This command can be used to prevent unwanted interference between different
maintenance processes. Maintenance software may put a component that is part
of a link in a busy state, causing link set-up to fail, and resulting in attempts by
the system to reestablish the link. If a maintenance test requires that the
component be idle, frequent attempts at re-setup may delay the recovery of a
faulty component. Busying out the link will prevent re-setup attempts.
Parameters
Examples
busyout journal-printer pms-log
busyout journal-printer wakeup-log
For more information see the following sections at the beginning of this chapter:
Busyout and Release Commands, Common Input Parameters, and Common
Output Fields.
C The cabinet is always
1
and need not be entered. On systems with duplicated
SPEs only, carrier
a
or
b
must be entered.
Simplex:
busyout host-adapter
Duplicated:
busyout host-adapter b
pms-log Busies out the link to the Property Management System printer