DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-487DID-TRK (Direct Inward Dial Trunk)
9
m. Incomplete Dial timer expired. This error only applies to the TN459 and
indicates a problem with incoming dialing stream. Refer the problem to the
CO.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below. By clearing
error codes associated with the
NPE Crosstalk Test
for example, you may also
clear errors generated from subsequent tests in the testing sequence..
NPE Crosstalk Test (#6)
The NPE Crosstalk Test verifies that this port’s NPE channel talks on the selected
time slot on the TDM bus and never crosses over to time slots reserved for other
connections. If the NPE is not working correctly, one-way and noisy connections
may be observed. This test is usually only part of a port’s Long Test Sequence
and takes about 20 to 30 seconds to complete.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1. D = Destructive; ND = Nondestructive
NPE Crosstalk Test (#6) X ND
Port Diagnostic Test (#35) X X ND
Looparound and Conference Circuit Test (#33) X ND
Port Audit Update Test (#36) X X ND
Table 9-200. TEST #6 NPE Crosstalk Test
Error
Code
Te s t
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources for this test. This could be
due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page