DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1326PPP-PT (Control LAN Packet/Port)
9
Error Log Entries and Test to Clear Value
Notes:
a. Error Type 001: SCOTCH Synchronous Looparound Test (#1275) failed.
1. Test the port (test port UUCSSpp long).
2. Refer to SCOTCH Synchronous Looparound Test (#1275) repair
procedures.
b. Error Type 257: CLAN port detected overrun or underrun condition that
may indicate a hardware problem.
1. Test for hardware problem (test port UUCSSpp long).
Table 9-516. CLAN Port Error Log Entries
Error Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test port UUCSSpp s
1 (a) 0 SCOTCH Sync
Looparound
Test (#1275)
MINOR ON test port UUCSSpp l r 3
257 (b) 0 Under-run/Over-run
Error
WARNING OFF
513 (c) 0 PPP Link Failure MINOR OFF
769 (d) 0 Invalid Frame Error WARNING OFF
1281 (e) 0 Far-end disconnect
1537, 1538
(f)
See
note
Session Status Test
(#1286)
MINOR OFF
1793-1920
(g)
See
note
Socket Failure
2305-2560
(h)
See
note
Session Down error
Session #s 1-256
2561-2816
(h)
See
note
Session Down error
Session #s 257-512
3329 (i) 35768 TCP/IP Ping Test
(#1281)
WARNING OFF
3585 (j) 0-1 TDM Looparound
Test (#1285)
MAJOR ON test port UUCSSpp l r 3
Continued on next page