A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-403CLAN-BD (Control LAN Circuit Pack)
9
Link Status Test (#601)
This non-destructive test sends a test frame over the signaling link to determine
whether the CLAN call control signaling link is connected.
Table 9-170. TEST #601 Link Status Test
Error
Code
Tes t
Result Description/ Recommendation
2012 ABORT Could not allocate the necessary system resources to run this test.
2100 ABORT Internal system error.
1. Retry command at 1-minute intervals, up to 5 times.
2 FAIL The RSCL control link disconnected.
1. Retry command at 1-minute intervals, up to 5 times.
2. If the test continues to fail, execute the Packet Interface Test (#598) to
determine if the problem is due to the circuit pack.
3. If the Packet Interface Test (#598) fails, refer to Packet Interface Test repair
procedures.
4. If the Packet Interface Test (#598) fails, refer to Packet Control Circuit Pack
and Packet Bus repair procedures.
3 FAIL Received no response to RSCL control link test frame.
1. Retry command at 1-minute intervals, up to 5 times.
2. If the problem persists, reset the circuit pack (reset board UUCSS).
3. If test continues to fail, replace the circuit pack.
PASS RSCL control link connected.
Continued on next page