A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-397CLAN-BD (Control LAN Circuit Pack)
9
PPE/LANBIC Receive Parity Error Counter Test
(#595)
This test is non-destructive. When the CLAN circuit pack detects a parity error
with a received frame, it increments the PPE/LANBIC Receive Parity error
counter. This test reads and clears the counter, and may verify repair of problem.
Errors may indicate a problem with
a circuit pack
a packet bus
another circuit pack on the bus
1, 2 FAIL The circuit pack failed to reset.
1. Retry command at 1-minute intervals, up to 5 times.
2. If the problem persists, pull out and reseat the circuit pack.
3. If the problem persists, replace the circuit pack.
PASS The circuit pack initialized correctly.
Table 9-165. TEST #595 PPE/LANBIC Receive Parity Error Counter Test
Error
Code
Tes t
Result Description/ Recommendation
2000 ABORT Did not receive circuit pack test response within the allowable time period.
1. Retry command at 1-minute intervals, up to 5 times.
2. If the problem persists, reset the circuit pack (reset board UUCSS).
3. If the problem persists, replace the circuit pack.
2100 ABORT Could not allocate the necessary system resources to run test.
2500 ABORT Internal system error.
1. Retry the command at 1-minute intervals, up to 5 times.
Continued on next page
Table 9-164. Test #252 Circuit Pack Restart Test — Continued
Error
Code
Tes t
Result Description/ Recommendation
Continued on next page