DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1339PRI-CDR/SEC-CDR (Call Detail Recording Link)
9
d. This error indicates that the CDR output device is in an off-line state, (for
example, due to paper jam or paper out for a printer device). The CDR link
is torn down. Check the CDR output device and act promptly to put it back
to on-line state. Enter
test cdr primary|secondary
command to set up the
CDR link.
e. Software detects an overflow of CDR records generated in the switch due
to the heavy trunk traffic and low speed CDR output device. If both
primary and secondary links are ON, the secondary link is torn down
temporarily for two minutes to speed up the output process to the primary
link. No action is necessary for this error type.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below when
inspecting errors in the system. By clearing error codes associated with the
Link
Retry Test
, for example, you may also clear errors generated from other tests in
the testing sequence.
Link Tear Down Test (#213)
This test is destructive.
This test disconnects the existing link between the system and the external CDR
output device. If the link has been disconnected already, this test just returns
PASS. All resources allocated for a CDR link are released after this test.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1. D = Destructive; ND = Nondestructive
Link Tear Down Test (#213) X D
Link Retry Test (#215) X X ND
Table 9-524. TEST #213 Link Tear Down Test
Error
Code
Te s t
Result Description/ Recommendation
40 ABORT Internal system error.
50 ABORT Internal system error.
1. Retry the command at one-minute intervals for a maximum of 5 times.
Continued on next page