DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-756EMG-XFER (Emergency Transfer)
9
Emergency Transfer Status
The
status cabinet
UU command shows the location of the ET switches and the
current status of ET in the designated cabinet as follows:
Error Log Entries and Test to Clear Values
System Technician-Demanded Tests: Descriptions
and Error Codes (Multi-Carrier)
Always investigate tests in the order presented in the table below. By clearing
error codes associated with the
Battery & Battery Charger Query Test,
for
example, you may also clear errors generated from other tests in the testing
sequence.
on
ET is manually invoked.
off
ET is manually prevented.
auto+
ET is invoked and under system control.
auto-
ET is not in effect and is under system control (normal
operating state).
unavailable
The switch setting(s) is not available.
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test environment UU
1 0 Emergency Transfer
Query (#124)
MAJOR ON test environment UU r 3
257 0 Emergency Transfer
Query (#124)
WARNING ON test environment UU r 3
Table 9-292. System Technician-Demanded Tests: EMG-XFER (Multi-Carrier
Cabinets)
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
Battery & Battery Charger Query Test (#5) (a) X X ND
Continued on next page