9-543DISK (MSS Disk Circuit Pack)
9
4. Verify that the files on all storage devices are consistent by issuing
the
test stored-data
command.
Error Log Entries and Test to Clear Values
The
Service State
field in the Alarm Log refers to the accessibility of the device.
IN (in service) means that users can access the device and all maintenance tests
Table 9-223. DISK Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
1 (a) any Disk Reset (#809) MINOR OFF reset disk a|b
1
1. In a system with simplex SPE, the carrier need not be specified. With duplicated SPEs, carrier a or b
must be specified.
18 (b) 0 Busyout Disk (#817) WARNING OFF release disk a|b
1
250 (c) 0 Reset Disk (#894) WARNING OFF reset disk a|b
1
257 (d) any Disk Looparound (#814) WARNING OFF test disk a|b
1
sh r 2
258 (e) any Disk Looparound (#814) WARNING OFF test disk a|b
1
sh r 2
513 (f) any Disk Diagnostics (#813) MINOR ON test disk a|b
1
sh r 2
526 (g) 0 Busyout Host-adapter WARNING OFF rel host-ad a|b
1
528 (h) 0 WARNING OFF
529 (i) 0 WARNING OFF reset disk a|b
1
769 (j) any Disk Looparound (#814) MINOR ON test disk a|b
1
sh r 2
1025 (k) any Disk Write-Read (#810) MINOR OFF test disk a|b
1
l r 2
1281 (l) any Disk Diagnostics (#813) MINOR ON test disk a|b
1
sh r 2
1793 (m) any Disk Looparound (#814) MINOR OFF test disk a|b
1
sh r 2
2049 (n) any Disk Looparound (#814) MINOR OFF test disk a|b
1
sh r 2
2305 (o) any Disk Status (#815) MINOR ON test disk a|b
1
sh r 1
2306 (p) 5504 Disk Frmwr Counters
(#812)
MINOR ON test disk a|b
1
sh
2561 (q) any Disk Write-Read (#810) MINOR OFF test disk a|b
1
l r 2
2817 (r) any Disk Status (#815) WARNING ON test disk a|b
1
sh r 2
3073 (s) any In-line MINOR ON test disk a|b
1
l r 2
3329 (t) any Disk Audit (#811) MINOR OFF test disk a|b
1
sh r 2
3841 (u)
2
2. If error type 1 with aux data of 123 is present, this field will indicate the cause of the out-of-service
condition. See the
MSS Error Actions
table at the end of the section on TAPE
Miscellaneous MINOR OFF test disk a|b
1
l r 1