
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-76display atm pnc
8
For the following example, the ENTER key was pressed immediately after entering
the
display alarms print
command.
Feature Interactions
If the alarm origination is disabled by “change system-parameters maintenance,”
the Ack? field displays blanks no matter what the true acknowledge state is for
the alarm.
If “second-as-backup” is administered in the Alarm Origination to OSS
Numbers field, the column under the “2” heading will be blank for the alarms that
the switch has not attempted to send to the second OSS telephone number. For
the alarms that the switch has attempted to send to the second OSS telephone
number, the column will be “y,” “n,” or “c,” depending on the acknowledgment
status of the alarm. After calling the first OSS telephone number becomes
successful, for the alarms that the switch has attempted to send to OSSN2, the
column will be consistent with the column under the “1” heading.
display atm pnc
This command displays specific atm pnc data.
display alarms
ALARM REPORT
Port Maintenance On Alt Alarm Svc Ack? Date Date
Name Brd? Name Type State 1 2 Alarmed Resolved
02A TONE-BD y MAJOR y n 05/22/20:34 00/00/00:00
01C07 ANL-BD y MINOR n n 05/22/20:26 00/00/00:00
01C0702 ANL-LINE n 311 WARNING IN 05/22/20:26 00/00/00:00
01C0701 ANL-LINE n 1051 WARNING IN 05/22/20:26 00/00/00:00
01C0703 ANL-LINE n 1053 WARNING IN 05/22/20:26 00/00/00:00
01C1505 CO-TRK n 78/01 WARNING OUT 05/22/20:26 00/00/00:00
01C1505 CO-TRK n 78/01 WARNING OUT 05/22/20:26 00/00/00:00
02A0201 TONE-PT n WARNING 05/22/20:34 00/00/00:00
02A TDM-CLK n WARNING 05/23/13:43 00/00/00:00
PN 02B TDM-BUS n WARNING 05/23/14:53 00/00/00:00
Command successfully completed