DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-145ASAI-PT
9
Clear Error Counters Test (#270)
There are various error counters associated with each ASAI-PT. This test clears
those counters and triggers the auditing of Layer 3 reinitialization. This test is
used only to send messages to the ASAI-PT and, therefore, should neither abort
nor fail. ASAI uses a fixed TEI value of 1.
Table 9-59. TEST #625 Receive FIFO Error Counter Test
Error
Code
Te st
Result Description/Recommendation
2000 ABORT Response was not received from the circuit pack within the allowable time
period.
1. If the test aborts repeatedly a maximum of 5 times, reset the circuit
pack via the busyout board UUCSS and reset board UUCSS
commands.
2. If the test aborts again, replace the circuit pack.
2012 ABORT Internal system error
2100 ABORT Could not allocate necessary system resources to run test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
Any FAIL The TN800 circuit pack is still detecting errors of this type. The Error Code
field contains the value of this counter.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2. If the test continues to fail, review the results of other tests in the Long
Test Sequence. Note the results of the Level 1 Status Inquiry test. Follow
repair procedures for any of the tests that fail. Otherwise, go to the next
step.
3. If the tests for the endpoints or adjunct pass and the Layer 1
Transmission Error Counter Test continues to fail, check the wiring to the
endpoints or adjunct.
PASS The Layer 1 Transmission error counter was read correctly and has a value
of 0.