9-199ATM-EI (Expansion Interface Circuit Pack)
9
ATM Board Error Query Test (#1259)
This test is non-destructive. The ATM circuit pack firmware maintains counters for
some of the on-board and off-board errors. The maintenance software queries
the board for its health information to do error analysis. These alarms have
assigned priority: if a higher priority alarm occurs, the remaining alarms are not
reported to the software (through the inline errors), avoiding unnecessary up-link,
in-line error message traffic. This is run as a part of a craft demand test sequence
periodic testing, initialization, and error analysis.
60XX, where
XX = DSP#
01-24
FAIL Cannot establish a looparound, because the previously established
looparound was not removed. The 60XX value indicates the DSP
number that has failed the test.
1. Retry the command at 1-minute intervals a maximum of 3 times.
2. If the test fails with the same error code replace the board.
PASS Test tone was correctly detected on both TDM Busses.
1. Refer to other ATM-EI circuit pack tests if the links between this
ATM-EI circuit pack and the ATM-EI or Switch Node Interface
circuit pack on the other end of the fiber are not functioning
correctly.
0NO
BOARD
No board was detected by the test.
1. Check the Error Log for wrong board (Error Type 125) or no
board (Error Type 131). Resolve either of these issues, if
applicable.
2. Check that the board is properly translated and inserted. If so,
check for hyperactivity (Error Type 1538). If hyperactive, use the
reset board UUCSS command.
3. Run the test again. If it fails, the NCE chip on the circuit pack
may be bad. Replace the circuit pack and retest.
Table 9-84. ATM Board DSP Test (#1258) — Continued
Error Code
Te st
Result Description/ Recommendation
Continued on next page