DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-503DIG-LINE (Digital Line)
9
Notes:
a. Could experience a noisy port or link. This is an off-board problem
detected by the port circuit. Check for defective wiring, a defective voice
terminal, or move voice terminal closer to the switch (in terms of feet of
wire from the jack to the switch). If the problem still exists, replace the
circuit pack. Once the problem has been resolved, the alarm will be
retired after a predetermined amount of time.
b. This Error Type and Aux Data will occur when at least 15 off-board
problems have been detected with the link to the terminal. When an error
with the link is detected, an on-board counter is incremented.
The user could experience a noisy port or link. This is an off-board
problem detected by the port circuit. Check for defective wiring, a
defective voice terminal, or move voice terminal closer to the switch (in
terms of feet of wire from the jack to the switch). If the problem still exists,
replace the circuit pack. Once the problem has been resolved, the alarm
will be retired after a predetermined amount of time.
1026(o) NONE WARNING OFF
1281 Any Station (Digital)
Audits Test (#17)
WARNING OFF test port
UUCSSpp
sh r 4
1537 (h) 40968 None WARNING OFF
1793 Voice & Ctrl. Local
Loop Test (#13)
MINOR/
WARNING
2
ON test port
UUCSSpp
l r 3
2049 NPE Crosstalk Test
(#9)
MINOR/
WARNING
2
ON test port
UUCSSpp
l r 3
2304 (n) None
2305 (i) 32770 None
2305 (h) 40967 None
3840 (k) 40965 None
3840 (l) 40989 None
3841 (m) 41029 None
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
2. Major alarms may be downgraded to Warning alarms based on the value used in the set options
command.
Table 9-205. Digital Line Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page