A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1252PKT-INT (Packet Interface Circuit Pack)
9
1025, (m) Any Private Looparound
Test (#885)
MAJOR
2
ON reset packet-interface CS
3
1026 Any None MAJOR
2
ON reset packet-interface CS
3
1281 (n) Any None MAJOR
2
ON reset packet-interface CS
3
1537 (o) Any Memory Checksum
Test (884)
MINOR ON test packet-interface CS l r
2
1793 (p) Any Memory Checksum
Test (#884)
MINOR ON test packet-interface CS l r
2
2049 (q) Any None WARNING ON test packet-interface CS r
25
2305 (r) Any None test packet-interface CS r 2
2561 (s) Any Active-Standby Peer
Link Test (#888)
MINOR OFF test packet-interface CS s r
2
2817 (t) Any Read and Clear Test
(#887)
MINOR/
MAJOR
2
ON test packet-interface CS s
3074,
3073,
3072 (u)
Any Maintenance
Looparound Test
(#886)
WARNING OFF test packet-interface CS s r
2
3329 (v) Any None WARNING OFF reset packet-interface CS
3
3585 (w) Any None WARNING OFF reset packet-interface CS
3
3841 (x) Any None MAJOR
2
OFF reset packet-interface CS
3
1. Indicates that an alarm was raised but an associated error was not entered into the hardware error
log due to a momentary overload condition caused by a burst of hardware or software error reports.
Run the long test sequence. Refer to the appropriate test descriptions for any failures and follow the
recommended procedures.
2. If a spontaneous interchange has occurred (as indicated by STBY-SPE error type 103 or the display
initcauses screen), and handshake is down, (check with status spe), replace the alarmed circuit
pack on the standby SPE. If handshake is up, execute a test long clear of the alarmed circuit pack
and follow recommended procedures.
3. A Packet Interface circuit pack on an active SPE can only be reset if it has been taken out of service
by background maintenance software. A Packet Interface circuit pack on a standby SPE can be
reset independent of its service state.
Table 9-497. Packet Interface Error Log Entries — Continued
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
Continued on next page