
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-132ASAI-EPT
9
System Technician-Demanded Tests:
Descriptions and Error Codes
When inspecting errors in the system, always investigate errors associated with
the circuit pack and port first. Clearing these error codes first may also clear
errors generated against the endpoint. When all circuit pack and port errors have
been cleared, but errors still exist against the endpoint, investigate errors in the
table below. By clearing error codes associated with the Signaling Link Status
Test, for example, you may also clear errors generated from other tests in the
testing sequence.
BRI Layer 3 Query Test (#629)
This test is not used by the ASAI-ADJ maintenance object. For information about
this test, see BRI-SET in the maintenance documentation.
79 Service or
option not
implemented
Requested service or option (or combination of selected options) is not
supported (implemented) in switch or the adjunct.
1. Consult switch and adjunct documentation to determine ASAI
service and options supported by both switch and adjunct.
Re-administration of the switch-administered capabilities (see
Customer Optional Feature Form) or those of the adjunct may be
necessary to correct the problem.
81 Invalid CRV An invalid CRV was sent by the adjunct.
1. This may indicate a CRV inconsistency between the switch and the
adjunct. See the CallVisor protocol reference manual.
87 Internal switch
audit
There is an inconsistency in switch data records.
1. There is no action needed, since the switch has corrected the data
inconsistency.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1. D = Destructive; ND = Nondestructive
Signaling Link Status Test (#626) X X ND
Table 9-51. ASAI Cause Values — Continued
Code Explanation Recommendation
Continued on next page