DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-147ASAI-RES/E-DIG-RES (TN800 reserve slot)
9
ASAI-RES/E-DIG-RES (TN800 reserve
slot)
There are no tests associated with these MOs. Both the
test board
and
busy out
board
commands abort when either is attempted on a reserved slot. An error
message indicates the slot is associated with the circuit pack that the TN800 is
emulating, but the requested operation is not valid.
The TN800 MAPD (Multi-Application Platform for DEFINITY) circuit pack
connects to the switch through a single slot in the backplane. The number of
slots occupied by the MAPD pack is supplied by the board when inserted. The
TN800 in R5EM is 3 slots wide. The TN800 requires 2 reserve slots to its left. The
reserve (blank) slots are to left of the functional slot and are place holders on the
switch, and do not have any interaction with the switch.
Each instance of these MOs represents a reserve slot associated with respective
circuit pack mode in which the MAPD is working.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to
Run Full Name of MO
ASAI-RES NONE NONE TN800 ASAI reserve slot
E-DIG-RES NONE NONE TN800 DIG reserve slot