DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-435CO-TRK (Analog CO Trunk)
9
1004 ABORT The port was seized by a user for a valid call.
1. Use the display port UUCSSpp command to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that
the port is in use, then the port is unavailable for certain tests. You must
wait until the port is idle before retesting.
2. If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
1005 ABORT Trunk has been administered as incoming-only; dial tone can only be
obtained on outgoing trunks. This is a normal condition.
1018 ABORT Test has been disabled via administration.
1. Verify that the "Maintenance Tests?" field on the Trunk Group Form is set
to "n." To enable the test, issue the change trunk-group x command
where "x" equals the number of the trunk group to be tested. Then
change the entry in the "Maintenance Tests?" field on the form to "y."
2000 ABORT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
FAIL Trunk was seized, but dial tone could not be detected.
1. Test all administered outgoing ports on the board. Failure of 1 indicates
a problem toward the CO.
2. If all fail, see note below.
3. Check for errors on the TONE-BD or TONE-PT. Clear any errors found,
and repeat the test.
4. If the error has still not cleared, refer the problem to the CO.
5. If no service problems exist on the port, continue to use the port until the
circuit pack can be replaced (as a last resort). Perform a trunk test call
to see if the trunk is operable.
NOTE:
If the dial tone test fails for all ports on a circuit pack, a -5 volt power
problem is indicated. To investigate problems with a power unit, refer
to “CARR-POW”.
Table 9-181. TEST #0 Dial Tone Test — Continued
Error
Code
Te st
Result Description/ Recommendation
Continued on next page