DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-327BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port)]
9
Layer 1 Transmission Error Counter Test (#624)
This test reads and clears the BRI port’s Layer 1 Transmission error counter
maintained on the BRI-LINE circuit pack. This counter is incremented by the
circuit pack when it detects a Layer 1 transmission problem. The test passes if
the value of the counter is 0 (that is, the error is cleared). If the counter is not zero,
the test fails, and the value of the counter is displayed in the Error Code field.
This error is most likely due to a problem with the wiring or the endpoint or
adjunct (verify that the wiring meets the configuration rules defined in
DEFINITY
Communications System Generic 1 and Generic 3i Wiring
, 555-204-111. It does
not indicate a problem with the ISDN-BRI circuit pack. This test is useful for
verifying the repair of the problem.
2012 ABORT Internal System Error.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1 FAIL The BRI-LINE circuit pack reports that it has detected an overcurrent
condition and has turned off the EPF.
1. As necessary, check and repair the wiring between the circuit pack and
the endpoint or adjunct. Check the endpoints and replace one or both
sets if the sets are drawing too much current. Execute the test port
PCSSpp command and review the results of the EPF Inquiry Test to
verify the repair. If this test is still failing, proceed to Step 2.
2. Execute the test port PCSSpp command, and review the results of the
Level 1 Status Inquiry Test. If this test is also failing, then follow the
repair procedure for the Level 1 Status Inquiry Test. Otherwise, escalate
this problem to the next tier.
PASS The Electronic Power Feed Inquiry Test reports that the EPF is on.
Table 9-144. TEST #622 Electronic Power Feed Inquiry — Continued
Error
Code
Te st
Result Description/ Recommendation
Continued on next page