DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1006MAPD-BD (MAPD Interface Circuit Pack TN802)
9
If there is no reply:
a. Check that the internal cables on the TN802 circuit pack (Notes 4
and 6 in Figure 9-57
) have not worked loose.
b. Otherwise, replace the circuit pack.
3. At the command prompt, type
ping 10.32.64.97
(the internal IP trunk
server address) and press
Enter.
If configured correctly, the system displays:
Reply from nnn.nn.nn.nn: bytes=32 time <##ms TTL=###
If there is no reply:
a. Check that the internal cables on the TN802 circuit pack (Notes 4
and 6 in Figure 9-57
) have not worked loose.
b. Otherwise, replace the circuit pack.
4. At the command prompt, type
ping 10.32.64.96
(the IP address of the
internal Motorola MPC860 processor) and press
Enter.
If configured correctly, the system displays:
Reply from nnn.nn.nn.nn: bytes=32 time <##ms TTL=###
If there is no reply:
a. Check that the internal cables on the TN802 circuit pack (Notes 4
and 6 in Figure 9-57
) have not worked loose.
b. Otherwise, replace the circuit pack.
5. Ping the gateway: at the command prompt, type
ping XX.XXX.XXX.XXX
(the IP address of the gateway) and press
Enter.
6. When finished, at the command prompt type
exit
and press
Enter.