9-1788TONE-BD (Tone-Clock Circuit Pack)
9
Error Log Entries and Test to Clear Values
Table 9-668. Tone-Clock Circuit Pack Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
0 Any Any Any test tone-clock PC sh
1(a) 0 Circuit pack removed
or SAKI Sanity Test
(#53)
MINOR ON
18(b) 0 busyout tone-clock PC WARNING OFF release tone-clock PC
23(c) 0 None WARNING OFF
125(d) None MINOR ON
126(e) None MINOR ON
257 65535 Control Channel Test
(#52)
MINOR ON test tone-clock PC r 20
257(f) Any None
513(g) Any None
769(h) 4358 None
1025(i) 4363 NPE Audit Test (50) test tone-clock PC sh
1538(j) Any None MINOR ON
2049(k) 0 Clock Health Inquiry
Test (#46)
MAJOR ON set tone-clock PC override
2305(k) 0 Clock Health Inquiry
Test (#46)
MAJOR ON set tone-clock PC override
2561(l) Any None MAJOR ON
3329(m) 0 None MINOR/
WARNING
2
2. Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
OFF set tone-clock PC
3840(n) Any None
3848(o) 0 Clock Health Inquiry
Test (#46)
set tone-clock PC override
3872(p) 0 None set tone-clock PC override
3999 (q) Any None