DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-227status bri-port
8
PN/SN
Each Port Network and Switch Node located in the cabinet is identified
by its PN number or its SN number and PNC designation (A or B).
Connectivity
Status
For PNs
connectivity status refers to the availability of the Expansion
Archangel Link (EAL) and Indirect Neighbor Link (INL) to the carrier for
both active and standby PNCs (if duplicated). Possible values are:
up EAL and INL are both available.
downEAL and INL are both unavailable.
near-endThe EAL is available and the INL is unavailable.
far-endThe INL is available and the EAL is unavailable.
blankIn the standby column, this means PNC is not duplicated.
For SNs
connectivity status indicates circuit pack insertion on the
Switch Node as follows:
up At least one switch node interface circuit pack in the Switch
Node is inserted.
downThere are no switch node interface circuit packs inserted on
the Switch Node.
blankIn the active column, this indicates that the Switch Node
carrier is currently the standby in a critical reliability system. In the
standby column, this indicates that the Switch Node carrier is
currently active (whether or not PNC is duplicated).
Emergency
Transfer
The location of the circuit pack containing the emergency transfer
select switch (EPN maintenance or SYSAM). In PPN cabinets with
duplicated SPEs, there are two such circuit packs. In this case, if the
standby Emergency Transfer Select switch is changed while
handshake is down, switch setting displayed will be incorrect until
handshake comes back up.
Select
Switch
The current setting of the emergency transfer switch:
on Emergency transfer has been manually activated.
off Emergency transfer is being manually prevented.
auto+ The cabinet is controlling emergency transfer and it is
currently activated.
auto- The cabinet is controlling emergency transfer it is not
currently activated.
unavail The current setting of the emergency transfer switch is not
available.
PN/SN Each Port Network and Switch Node located in the cabinet is identified
by its PN number or its SN number and PNC designation (A or B).
Mj, Mn, Wn The number of major, minor and warning alarms currently logged
against the Port Network or Switch Node.