A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1469SNI-BD (SNI Circuit Pack)
9
2303 ABORT The SNI circuit pack responded that the software test requested is invalid.
1. Retry the command at 1-minute intervals a maximum of 3 times.
2304 ABORT SNI firmware is not able to run the test. For this particular test, the SNI circuit
pack must be able to communicate with its neighbor.
1. Verify that the SNI can communicate with its neighbor by checking the
yellow LED of the SNI to make sure the SNI is in frame or by running the
test board command for the SNI and checking test 989 for fiber
out-of-frame. If the results of Test 989 indicate that the fiber is out-of-frame,
follow the recommendation associated with the test failure. If a DS1
converter complex exists on the fiber link, enter display errors and follow
the associated repair procedures for any DS1C-BD and DS1-FAC entries.
2. Retry the command at 1-minute intervals a maximum of 3 times.
2306 ABORT The SNI circuit pack is not responding to test requests sent by software.
1. Run the test led switch-node for the switch node carrier that the SNI
resides in to verify whether the LEDs on the board light.
2. If the LEDs on the other boards in the carrier light, but the LEDs on this
board do not light, run test 760 via test board UUCSS l for the active SNC
in this carrier. Wait 5 minutes and then try step 1 one more time. If the
LEDs on this board still do not light, replace this board. Replacing an SNI
may be service interrupting. Refer to the SNI-BD section for the procedure
for replacing an SNI.
3. If none of the LEDs light for the boards in the same carrier as this board, fix
any problems associated with the connectivity of this carrier to the SPE.
Check list fiber-link to determine the fiber connections to this carrier.
Check the LEDs on all SNIs and EIs and fix any fiber problems. Enter
display errors and follow the associated repair procedures for any
EXP-INTF error entries associated with the PPN. Also, follow the
associated repair procedures for any SYNC, SNI-BD, SNC-BD, FIBER-LK,
or SNI-PEER error entries.
4. Follow the procedure described above, SNI Manual Loopback to
determine whether the circuit pack or the fiber connection is faulty.
Table 9-564. TEST #767 Packet Neighbor Link Test — Continued
Error
Code
Tes t
Result Description/ Recommendation
Continued on next page