DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-484DID-TRK (Direct Inward Dial Trunk)
9
Problems detected during signaling may be caused by off-board faults in the CO
switch or connections for which a Warning alarm is raised.
Before a maintenance test can be run on a port, the port must be idle. If an
incoming call seizes a port that is being tested, the test will abort and the
incoming call will proceed.
For transmission and signaling standard specification, refer to
Digital PBX
Standards
, RS4648.
Ports Out-of-Service without Errors or Alarms
A common trouble on DID trunks that produces no errors or alarms occurs when
the CO busies out (disconnects) the port. This situation occurs when the CO
thinks there are problems with the DID port. In this case, no incoming calls will be
possible through this port. This may result in complaints from outside callers
trying unsuccessfully to call in. This problem can be diagnosed by listing
measurements on lightly used trunks. If a particular port is detected as not in
use, a call to the CO will be necessary to get the connection back in service.
Error Log Entries and Test to Clear Values
Table 9-199. DID Trunk Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test port
UUCSSpp
sh r 1
1(a) Any None WRN OFF
1(b) 57476 None WRN OFF
1(c) 57477 None WRN OFF
1(d) 57483 None WRN OFF
15(e) Any Port Audit Update
(#36)
18 0 busyout trunk
grp/mbr
WRN OFF release trunk
grp/mbr
130(f) None WRN ON test trunk
grp/mbr
257(g) 57472 None WRN OFF
257(h) 57473 None WRN OFF
257(i) 57474 None WRN OFF
257(j) 57475 None WRN OFF
513(k) 57392 None MIN/ WRN
2
OFF
510(l) 57393 None
Continued on next page