Maintenance Object Repair Procedures
9-485DID-TRK (Direct Inward Dial Trunk)
9
Notes:
See also the preceding section on trunk problems without errors or alarms.
a. This condition occurs when the tone detector times out waiting for digits.
Change wink/immediate-start parameter to wink/immediate-start and
rotary/tone-dial parameters.
1. Verify trunk administered wink/immediate-start parameter.
2. Test trunk using BUTT set.
3. Refer problem to CO.
b. Rotary dial before wink
This condition occurs when the CO starts
dialing before the PBX sends wink on a wink-start trunk.
1. Verify trunk administered wink/immediate-start parameter.
2. Refer problem to CO.
c. Rotary dial too early
This condition occurs when the CO starts dialing
too soon after seizure on an immediate-start trunk.
1. Verify trunk administered wink/immediate-start parameter.
2. Refer problem to CO.
d. Rotary dial pulse during wink
This condition occurs when the CO
sends rotary dial digits too soon after seizure on a wink-start trunk.
1. Verify trunk administered wink/immediate-start parameter.
769 Any Port Diagnostic
(#35)
MIN/ WRN
2
ON test port
UUCSSpp
r 3
1025 Looparound and
Conference (#33)
MIN/ WRN
2
ON test port
UUCSSpp
l r 3
1281 NPE Crosstalk (#6) MIN/ WRN
2
ON test port
UUCSSpp
l r 3
1537 Any Port Diagnostic
(#35)
MAJ/ MIN/
WRN
2
OFF test port
UUCSSpp
r 3
1793(m) 57489 None None
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2. Major alarms may be downgraded to Warning alarms based on the value used in the set options
command.
Table 9-199. DID Trunk Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page