Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-337test eda-external-device-alrm
8
Examples
test eda-external-device-alrm all
test eda-external-device-alrm all schedule
test eda-external-device-alrm physical 1major r 10
test eda-external-device-alrm physical 2c1101 c
Output
For the following output example the command that was entered was
test
external-device-alarm all
:
The responses are displayed on a test-by-test basis with one line of data
displayed for each test result.
Field definitions:
Port
The port address (cabinet-carrier-slot-circuit) of the maintenance
object that is being tested.
Maintenance
Name
The type of maintenance object that is being tested.
Alt. Name The alternate means of identifying the MO. This is an administered more
descriptive name of the external device alarm
Test No The actual test that is being executed.
Result The result of the individual test -PASS, ABORT, FAIL,NO BOARD,
DISABLED, EXTRA BD.
test eda-external-device-alrm all
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
03major EXT-DEV CMS1 120 PASS
03A2102 EXT_DEV CMS2 120 FAIL
01major EXT-DEV UPS1 120 PASS
01minor EXT-DEV UPS1 120 PASS
01c1201 EXT-DEV UPS1 120 PASS
03A2101 EXT_DEV CC temp 120 PASS
01c1202 EXT-DEV Audix1 120 PASS
03minor EXT-DEV Audix2 120 FAIL
04major EXT-DEV unknown 120 FAIL
Command successfully completed