555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-913HYB-LINE (Hybrid Line)
9
sensed (that is, too much current is being drawn), this may indicate a short in the
loop or a defective voice terminal. A message is returned stating that either the
EPF was turned on successfully, or that an overcurrent condition exists. This test
is repeated once more 5 seconds later. If either test is not successful, the test will
abort (see first ABORT entry in Table 9-350
).
Table 9-350. TEST #56 Hybrid Electronic Power Feed Test
Error
Code
Tes t
Result Description/ Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the station
extension number of the port. Use the status station command to
determine the service state of the port. If the port is in use, wait until the
port is idle before testing.
2. If the port staLus is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS Electronic Power Feed test passed. The message to turn on the power to the
station was successfully sent to the port.
1. Although this test will never actually return a FAIL result except for the
Internal system error described above, it will log an error if the overcurrent
case is detected by the hardware. Check the Error Log for any entries with
Error Type 257 when the test has completed.
2. If Error Type 257 does not appear in the Error Log within 10 seconds after
completion of this test, it is safe to assume that the test sensed no problems
with the power to the station. To verify that the station is powered up
correctly, run a self-test on the station, if available, and check that all the
feature buttons are operating.
3. If Error Type 257 appears in the Error Log, this indicates some problem with
the power to the station. Check for a short in the wiring, a damaged jack, a
defective voice terminal, or an incorrect type of terminal.