
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1287PMS-LINK (Property Management System Link)
9
Link Retry Test (#215)
This test sends a message to the PMS software process to make a data call to
the extension where the PMS device connects. If the PMS Link is already up, then
this test passes without making any data call.
Table 9-505. TEST #213 Link Tear Down Test
Error
Code
Tes t
Result Description/ Recommendation
40
50
ABORT Internal system error.
1. Retry the command at one-minute intervals a maximum of 5 times.
1010 ABORT The PMS Link has been busied out and placed in the out-of-service state.
1. Enter release pms-link command to release the PMS Link from busyout
state.
2. Retry test pms long command to execute the test.
2012 ABORT Internal system error.
1. Retry the command at one-minute intervals a maximum of 5 times.
FAIL Internal system error.
1. Retry the command at one-minute intervals a maximum of 5 times.
PASS The PMS Link is torn down.
Table 9-506. TEST #215 Link Retry Test
Error
Code
Te s t
Result Description/ Recommendation
10
20
ABORT Internal system error.
1. Retry the command at one-minute intervals a maximum of 5 times.
30 ABORT Internal system error.
1. Refer back to the ‘‘Procedures for Restoring the PMS Link’’ section for
resolution.
1010 ABORT The PMS Link has been busied out and placed in the out-of-service state.
1. Enter release pms-link command to release the PMS Link from
busyout state.
2. Retry test pms command to execute the test.
Continued on next page