Maintenance Object Repair Procedures
9-735DUPINT (Duplication Interface Circuit Pack)
9
Tests listed as
destructive
are so designated because they require shadowing to
be turned off. For testing to resolve DUPINT alarms, the alarmed circuit pack
must be on the Active SPE carrier.
Control Register Test (#865)
This test checks the operation of the control register located on the Duplication
Interface circuit pack.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1. D = Destructive, ND = Non-destructive
Active DUPINT HFAIL Check Test (#979) X X ND
Active DUPINT Reset Test (#870) X D
Control Register Test (#865) X ND
Mailbox Loop-around Test (#866) X D
Local Loop-around Test (#867) X D
Memory Shadow Bounds Test (#868) X D
Table 9-282. Test #865 Control Register Test
Error
Code
Tes t
Result Description/ Recommendation
1418 ABORT The HFAIL bit and/or the STDONE bit is in the wrong state. The active
Duplication Interface circuit pack needs to be reset.
1. Run the test duplication-interface long command and follow instructions
for the Active DUPINT Reset Test (#870).
2. If test #870 passes and this test still aborts, escalate the problem.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL The Control Register test bit was not set in the Status Register and the
Type/Suffix/Vintage Register after this bit was written into the Control Register.
1. Replace Duplication Interface components starting with the active
Duplication Interface circuit pack. Use SPE Duplication Channel
Component Replacement procedures at the end of this section.
PASS The Control Register test bit was set in the Status Register and the
Type/Suffix/Vintage Register after this bit was written into the Control Register.