DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-393CLAN-BD (Control LAN Circuit Pack)
9
1. Refer to Congestion Query Test (# 600) for Abort and Fail Error
Codes.
n.
Error Type 3073
: Remote Socket Control Link (RSCL) or Link Status Test
(#1279) failed. This failure may be due to the
■ circuit pack
■ packet bus
■ packet interface circuit pack .
o.
Error Type 3330
: Critical failure in Packet Bus interface.
Below, Error Types correspond to descriptions.
1. Attempt to clear the alarm (
reset board UUCSS
).
2. If alarm persists, replace circuit pack.
p.
Error Type 3586 and 3999
: Switch removed hyperactive circuit pack that
reported threshold number of errors. One or more of the following
symptoms may be present:
■ Circuit pack port tests return NO BOARD.
■ List configuration command shows circuit pack and ports are
installed properly
If: Then:
Active buffers exceed threshold, CLAN enters congested state.
If: Then:
RSCL disconnects at link level Link fails
Link cannot be reconnected quickly Switch raises MINOR alarm
1292 Internal hardware component failed
1293 Insane on-board auxiliary processor
If the switch detects: Then it:
1 error, Resets circuit pack.