DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-474DID-DS1 (Direct Inward Dial Trunk)
9
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1—DS1 Interface circuit pack detects a hardware error on the
DS1 DID trunk. The Aux Data field indicates the following:
DID-DS1 Trunk Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test trunk
grp#/mbr#
1(a) Any
15(b) Any Port Audit and
Update Test (#36)
18(c) WARNING OFF release trunk
grp#/mbr#
130(d) None WARNING ON test trunk
grp#/mbr#
257(e) 57474
57473
513(f) 57392 MIN/MAJ
2
2. This alarm will only be raised when the System-Parameter Country form has the Base Tone Generator
field set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this trunk group
are out of service, then the alarm will be upgraded to a MAJOR alarm.
769(g) 57393 MIN/MAJ
2
1281 Conference Circuit
Test (#7)
MIN/
WRN
3
3. Major alarms may be downgraded to Warning alarms based on the value used in the set options
command.
ON test trunk
grp#/mbr#
l r 4
1537 NPE Crosstalk
Test (#6)
MIN/
WRN
3
ON test trunk
grp#/mbr#
l r 3
1793(h) test board
UUCSS
l
2305(i) 50944 None MIN/MAJ
2
OFF
3840(j) Port Audit and
Update Test (#36)
57476 On-hook before wink
57477 On-hook before ready to receive digits
57485 Wink too short for valid signal