A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-344BRI-SET, ASAI-ADJ, BRI-DAT
9
p. For Error 2568 indicates that the adjunct id is invalid, check the vender id
or software running on the Lucent adjunct
System Technician-Demanded Tests:
Descriptions and Error Codes
When inspecting errors in the system and deciding which ones to address,
always investigate errors associated with the circuit pack and port first. Clearing
these error codes first may also clear errors generated against the endpoint.
When all circuit pack and port errors have been cleared, and errors still exist
against the endpoint, always investigate errors in the order they are presented in
58 Bearer
Capability Not
Presently
Available
Requested bearer capability is implemented,
but not administered. No B-channel
administered. See recommendation 50 above.
65 Bearer Service
Not
Implemented
Requested service not implemented in switch
or endpoint.
69 Requested
Facility Not
Implemented
Requested service not supported in switch or
endpoint.
1. Consult switch and endpoint
documentation to determine service
support.
2. If Step 1 does not resolve the problem,
escalate to the next tier.
81 Invalid CRV An invalid CRV was sent by the adjunct.
1. This may indicate a CRV inconsistency
between the switch and the adjunct. See
the CallVisor protocol reference manual.
2. If step 1 does not resolve the problem,
escalate to the next tier.
Table 9-150. ISDN-BRI CAUSE VALUES — Continued
Error
Code Test Result Description/ Recommendation
Continued on next page