A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-520DIOD-DS1 (DS1 DIOD Trunk)
9
Three trunk service states are specified by DS1 DIOD trunk maintenance:
Error Log Entries and Test to Clear Values
out-of-service The trunk is in a deactivated state and cannot be used
for either incoming or outgoing calls.
in-service The trunk is in an activated state and can be used for
both incoming and outgoing calls.
disconnect
(ready-for-service)
The trunk is in an activated state but can only be used for
an incoming call.
DS1 DIOD Trunk Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test trunk <grp>/<mbr>
1(a) 57408
1(a) 57487
57476
57477
57485
15(b) Any Port Audit and
Update Test (#36)
18(c) 0 busyout trunk
<grp>/<mbr>
WARNING OFF release trunk
<grp>/<mbr>
130(d) None WARNING ON test trunk <grp>/<mbr>
257(e) 57392 DS1 CO Dial Tone
Seizure Test (#314)
MIN/MAJ
2
OFF
513(f) 57393 DS1 CO Dial Tone
Seizure Test (#314)
MIN/MAJ
2
OFF
769(g) 57484
1025(h) 51200
1025 DS1 CO Dial Tone
Seizure Test (#314)
MIN/
WRN
3
OFF test trunk <grp>/<mbr>
r 2
1281 Conference Circuit
Test (#7)
MIN/
WRN
3
ON test trunk <grp>/<mbr>
l r 4
1537 NPE Crosstalk Test
(#6)
MIN/
WRN
3
ON test trunk <grp>/<mbr>
l r 3
1793(i) test board UUCSS l
2049(j) 57473
57474
57475