A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-164ATM-DCH (ATM D-Channel Port)
9
System Technician-Demanded Tests: Descriptions
and Error Codes
The command to test the ATM-DCH maintenance object is
test port UUCSSpp
,
where pp is for ports 9-32.
Signaling Link Board Check (#643)
This nondestructive test checks the health of the ATM TN230X Trunk circuit pack
hardware. The test runs on a periodic or scheduled basis, during initialization
testing, and upon demand.
NOTE:
The board-level maintenance is handled independently of the ATM-CES
signaling link maintenance, raising the possibility of inconsistent states.
Table 9-70. System Technician-Demanded Tests: ATM-DCHL
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1. D = Destructive, ND = Non-destructive
Signaling Link Board Check (#643) X X ND
Continued on next page
Table 9-71. TEST #643 Signaling Link Board Check
Error
Code
Te s t
Result Description/ Recommendation
ABORT Internal System Error
1. Retry the command at 1-minute intervals for a maximum of 5 times.
8 FAIL The TN230X circuit pack is not in-service.
1. Check the Error Log for ATM-TRK errors and resolve any using β€˜β€˜ATM-TRK
(Circuit Emulation Service Circuit Pack)’’.
PASS The ATM TN230X circuit pack is in-service.
Continued on next page