DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-321BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port)]
9
Electronic Power Feed Restoral Test (#620)
This test attempts to restore the Electronic Power Feed (EPF) on an ISDN-BRI
port twice. In this test, the processor requests that the EPF be turned on for a
given port. An attempt is made to turn on the power unit to the station or adjunct.
If no current is being drawn by a station, this probably indicates that the station is
not connected. No current being drawn by an adjunct is the normal condition. If
an overcurrent condition is sensed (that is, too much current is being drawn), this
condition may indicate a short in the wiring to the endpoint or adjunct.
2000 ABORT Response to the test was not received from the BRI-LINE circuit pack within
the allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack if the
other ports are not in use. Reset the circuit pack by issuing the busyout
board PCSS and the reset board PCSS commands.
2. If this result occurs again, replace the circuit pack.
2012 ABORT Internal System Error.
2100 ABORT Could not allocate the necessary resources to run this test.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
2103 ABORT The system could not make the conference connection for the test.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1
2
FAIL As stated previously, this test runs a TDM Loop Around Test on each
B-channel. This indicates that the loop around failed on one of the channels.
Error Code 1 indicates that the TDM Loop Around Test failed on B1. Error
Code 2 indicates that the TDM Loop Around Test failed on B2.
7
8
FAIL As stated previously, this test runs a Conference Circuit Test on each
B-channel. A failure here indicates that one of these conference tests failed;
Error Code 7 means that the test failed on B1; Error Code 8 means that the
test failed on B2.
1. If the test fails repeatedly, attempt to reset the circuit pack if the other
ports on the circuit pack are not in use. Reset the circuit pack by issuing
the busyout board PCSS and the reset board PCSS commands.
2. If the test fails again, replace the circuit pack.
PASS The BRI Port Local TDM Loop Around Test has passed.
Table 9-141. Test #619 BRI Port Local TDM Loop Around — Continued
Error
Code
Te s t
Result Description/ Recommendation
Continued on next page