A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-414CO-DS1 (DS1 CO Trunk)
9
f. Error Type 513
The DS1 Interface circuit pack detects a hardware fault.
Aux Data 57393 indicates belated external release on PBX disconnect.
g. Error Type 769
The DS1 Interface circuit pack detects a hardware fault.
The Aux Data field contains the following error type:
57484, fault is
detected on tip/ring.
h. Error Type 1793
DS1 Interface circuit pack is out-of-service. Look for
DS1-BD errors in the Hardware Error Log if the port is on a TN767 DS1
board. Look for UDS1-BD errors in the Hardware Error Log if the port is on
a TN464 UDS1 board. Refer to the DS1-BD or UDS1-BD (DS1 Trunk Circuit
Pack) Maintenance documentation for details
i. Error Type 2562
Retry Failure error. This error is logged only. It is not a
hardware failure and hence does not start any testing or generate any
alarms. This error comes from call processing and is generated when a
second attempt (retry) to seize an outgoing trunk fails.
j. Error Type 2817
Glare error. This error is logged only. It is not a hardware
failure and hence does not start any testing or generate any alarms. This
error is the result of a simultaneous seizure of a two-way trunk from both
the near-end and the far-end. Attempt to place the call again. If the error
persists, execute the Dial Tone Seizure Test (#314) and follow those
procedures.
k. Error Type 3840
Port Audit and Update Test (#36) failed due to an
internal system error. Enter the
status trunk
command to verify the status
of the trunk. If the trunk is out-of-service, then enter the
release trunk
command to put it back into in-service. Retry the test command.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order they are presented in the table below when
inspecting errors in the system. By clearing error codes associated with the
NPE
Crosstalk Test,
for example, you may also clear errors generated from other tests
in the testing sequence.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1. D = Destructive; ND = Nondestructive
NPE Crosstalk Test (#6) X ND
Conference Circuit Test (#7) X ND
DS1 CO Trunk Seizure Test (#314) X X ND
Port Audit and Update Test (#36) X X ND