Maintenance Object Repair Procedures
9-286AUDIX-PT (AUDIX Port)
9
AUDIX-PT (AUDIX Port)
The AUDIX-PT maintenance object represents a port on a TN566/TN2169
DEFINITY AUDIX circuit pack operating in digital-port (DP) mode. For
circuit-pack-level problems (AUDIX-BD), see “XXX-BD (Common Port Circuit
Pack)”.
The maintenance strategy for ports on the TN566 operating in control-link mode
is described in ADX16A-PT.
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run
1
1.
UU
is the universal cabinet number (1 for PPN, 2 - 44 for EPNs).
C
is the carrier
designation (A, B, C, D, or E).
SS
is the number of the slot in which the circuit pack
resides (01 to 21).
pp
is the two digit port number (01, 02, ...).
Full Name of
MO
AUDIX-PT MINOR test port UUCSSpp l AUDIX Port
AUDIX-PT WARNING test port UUCSSpp sh AUDIX Port