9-169ATM-EI (Expansion Interface Circuit Pack)
9
2. If the ATM PNC EI circuit pack is not present or is present but it is in an
EPN that does not yet have PNC connectivity to it, use the
change
circuit-pack
command to add circuit pack translation for the missing
circuit pack.
3. Enter
add atm pnc
n
(connection number), and administer the circuit
pack location and ATM address.
4. Enter
change system-parameters duplication
and change the
Enable
Operation of PNC Duplication
field to
y
.
Removing ATM PNC connections
Standard Reliability
NOTE:
Standard Reliability systems are
not
equipped with PNC duplication.
1. Enter
busyout atm-pnc
n
(connection number)
2. Enter
remove atm-pnc
n
(connection number)
Critical Reliability
1. Enter
status pnc
and ensure that the A-PNC is active. If it is not active,
request a PNC interchange using the
reset pnc interchange
command.
2. Enter
busyout pnc-standby
.
3. Enter
change system-parameters duplication
and change the
Enable
Operation of PNC Duplication
field to
n
.
4. Enter
busyout atm-pnc
n
(port network number).
5. Enter
remove atm pnc
n
(port network number) to remove both ATM PNC
EI boards, or enter
change atm pnc
to remove the B-side ATM PNC EI
board.
6. Enter
change system-parameters duplication
and change the
Enable
Operation of PNC Duplication
field to
y
.
Changing circuit pack location or ATM address
Standard Reliability
NOTE:
Standard Reliability systems are
not
equipped with PNC duplication.
1. Remove the ATM PNC connection (see ‘‘Removing ATM PNC
connections’’ above).
2. Add an ATM PNC connection (see ‘‘Adding ATM PNC connections’’
above).