DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-339BRI-SET, ASAI-ADJ, BRI-DAT
9
If the error type is greater than 3712, then the ASAI cause code is equal to
the error type minus 3712. This code was sent to the adjunct by the
switch.
If the error type is less than 3712, then the ASAI cause code is equal to the
error type minus 3584. This code was sent to the switch by the adjunct.
A description of the various ASAI cause values is contained in the Ta b l e
9-149. This table also contains recommended system technician actions
associated with the cause value. Further information can also be found in
the Lucent ASAI Specification (288-500-03). In addition, the Aux Data field
of the Error Log entry contains additional diagnostic information additional
diagnostic.
Table 9-149. ASAI CAUSE VALUES
Error
Code Test Result Description/ Recommendation
0 Unrecognized
ASAIProtocol
Operation
Requested ASAI protocol operation is not
implemented by the switch or adjunct. Aux
Data field of Error Log entry contains
protocol identifier for unrecognized
operation.
1. Consult switch and adjunct
documentation to determine which set
of operations is supported by the switch
and the adjunct. Adjunct administration
turning off operations not implemented
by the switch may resolve the problem.
2. If Step 1 does not resolve the problem,
escalate to the next tier.
40 Resources not
available
No available internal resources to service
switch or adjunct request. System
transaction capacity for adjunct or switch is
exceeded.
1. Re-engineering of adjunct services my
be required. If problem persists,
escalate problem to the next tier.
Continued on next page