A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-170ATM-EI (Expansion Interface Circuit Pack)
9
A-side ATM PNC EI — Critical Reliability
1. Remove the ATM PNC connection (see ‘‘Removing ATM PNC
connections’’ above).
2. Add an ATM PNC connection (see ‘‘Adding ATM PNC connections’’
above).
B-side ATM PNC EI — Critical Reliability
1. Enter
status pnc
and ensure that the A-PNC is active.
If it is not active, request a pnc interchange using the
reset pnc
interchange
command.
2. Enter
busyout pnc-standby
.
3. Enter
list config car
and verify that an ATM circuit pack is administered
for the new location. If it is not, add the ATM circuit pack translations.
4. Enter
busyout atm pnc
n
(connection number)
b-pnc
.
5. Enter
change atm pnc
n
(connection number) and change circuit pack
location for the B side.
6. Enter
release pnc-standby
.
Changing ATM address of a B-side ATM-PNC EI — Critical Reliability
1. Enter
busy pnc-standby
.
2. Enter
change atm pnc
n
(connection number) and change the ATM
address for the B side.
3. Enter
release pnc-standby
.
Error Log Entries and Test to Clear Values
Table 9-74. ATM-EI Error Log Entries
Error
Type
Aux
Data
1
Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
2
0 Any Any Any test board UUCSS
2 (a) None MIN ON
18 (b) 0 busy out board UUCSS WAR OFF release board UUCSS
23 (c) 0 None WAR OFF
125 (d) None MIN ON
131 (e) None MIN ON
Continued on next page