9-389CLAN-BD (Control LAN Circuit Pack)
9
Error Log Entries and Test to Clear Values
Table 9-162. CLAN-BD Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
1(a) 0 MINOR ON
18 (b) WARNING OFF release board UUCSS
217 (c) 0 None WARNING ON
257 65535 Control Channel
Loop Test (#52)
MINOR ON test board UUCSS l r 20
257 (d)
513 (e) 4352-
4357
MINOR ON
769 (f) 4358
1291 to
1296 (g)
MINOR ON reset board UUCSS
1537(h) Any MINOR ON
1793-
1795 (i)
MINOR ON
2049 (j) Packet Interface
Test (#598)
MINOR ON test board UUCSS l r 3
2305
2306 (k)
2561 to
2668 (l)
Any Socket Error
2817
2819 (m)
Congestion Query
Test (#600)
MINOR ON test board UUCSS s r 3
3073 (n) PPP Link Status
Inquiry Test (#1279)
MINOR ON test board UUCSS s
3330 (o) MINOR ON reset board UUCSS
3586 (p)
3840 (q) 4096-
4100
3841
3843 (r)
Continued on next page