A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1607SYSAM (Circuit Pack)
9
Sanity Handshake Test (#911)
This test checks the SYSAM circuit pack’s ability to respond to queries. A
message is sent to the SYSAM circuit pack, which then returns a message. The
SYSAM must reply for this test to pass. If this test fails, the SYSAM circuit pack
should be considered insane, the circuit pack should be reset with the
reset
maintenance a | b
command.
2334 ABORT The hardware mailbox on the standby Duplication Interface board is not ready
to receive messages.
1. Retry the command at 1-minute intervals, a maximum of 5 times.
FAIL The DPR is not functioning correctly. Communication between the Processor
and SYSAM is lost. The system is not able to report environmental alarms, use
the PPN G3-MT, or use the SYSAM Remote Access connection if the need
should arise.
1. Retry the command.
2. If the test continues to fail, replace the SYSAM circuit pack.
3. Retry the command.
4. If the test continues to fail, replace the Processor circuit pack.
5. Retry the command.
6. Replace the SPE circuit packs. See ‘‘Replacing SPE Circuit Packs’’
in
Chapter 5.
PASS Dual Port RAM is functioning. Communication does exist between the
Processor and SYSAM circuit packs.
Table 9-607. Test #911 Sanity Handshake Test
Error
Code
Te st
Result Description/ Recommendation
100 ABORT The requested test did not complete within the allowable time period.
1. Retry the command.
1000 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals, a maximum of 5 times.
Continued on next page
Table 9-606. Test #910 SYSAM Dual Port RAM Test — Continued
Error
Code
Tes t
Result Description/ Recommendation
Continued on next page