DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-999MAPD-BD (MAPD Interface Circuit Pack TN802)
9
NOTE:
Local restore of a complete system from the PCMCIA disk should not
require more than 20 minutes assuming that a replacement MAPD pack is
available and pre-loaded with the IP trunk application software.
Restoring data from the PCMCIA disk
Before you start
1. Shut down the application running on the circuit pack. See ‘‘Shutting down
NT on the TN802’’.
2. Remove the defective IP Trunk circuit pack from the switch (if applicable).
3. Install the replacement IP Trunk circuit pack in the switch (if applicable).
4. Insert the backup diskette into the IP Trunk circuit pack.
3. Select utility In the IP Trunk Backup/Restore Utility dialog
screen, click on Files, Backup.
The IP Trunk Backup screen appears.
4. Select backup In the IP Trunk Backup screen, click on the
Backup button
5. Wait Backup can take as much as 20 minutes to
complete.
6. Release circuit pack At the DEFINITY ECS terminal type release board
UUCss (the address of the TN802 circuit pack)
and press
Enter.
Table 9-386. Restore TN802 administration data
Step Description Comments
1. Restore IP Trunk
administration
At the Windows NT desktop, double-click on the
IP Trunk Back UP Restore icon.
The IP Trunk Backup/Restore Utility screen
appears.
Continued on next page
Table 9-385. Backing up TN802 administration data — Continued
Step Description Comments
Continued on next page