DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-706DUP-CHL (Duplication Interface)
9
Remote Loop-Around Test (#869)
This test is destructive
.
This test writes a word to a memory address on the active SPE that is inverted
and is looped back by the standby Duplication Interface circuit.
Table 9-273. TEST #869 Remote Loop-Around Test
Error
Code
Tes t
Result Description/ Recommendation
1321 ABORT The faceplate switches on the Duplication Interface circuit packs are not set to
auto.
1. If the switches are locked because you are using a replacement
procedure, continue with this procedure to the step that directs you to
unlock the active SPE by moving both switches to auto. The next step
using the test duplication-interface long clear should not abort with this
error code.
2. If the switches are locked and a replacement procedure is not being used,
start with step 6 of the SPE Duplication Channel Component Replacement
procedure for the standby
3. Duplication Interface Circuit pack at the end of this DUP-CHL section to
avoid an undesired interchange when unlocking the active SPE. If this
same abort is received with both switches in auto, Replace Duplication
Interface components starting with the standby Duplication Interface
circuit pack. Use SPE Duplication Channel Component Replacement
procedures at the end of this DUP-CHL section. In addition to looking for
failures, also check for the absence of this 1321 abort code when testing
after the procedure directs setting the switches to auto after a component
replacement.
1405 ABORT This test did not run because the Duplication Channel was busy.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1411 ABORT This test did not run because the standby Duplication Interface circuit pack
cannot be detected as being plugged in by the software.
1. If this abort continues to occur, the standby SPE may not have initialized
properly. Use the lock-and-power-down procedure described in Chapter 5
to power down and power up the standby SPE, but don’t replace any
circuit packs.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page