DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1196PGATE-BD (Packet Gateway Circuit Pack)
9
Notes:
a. This error indicates that the circuit pack has stopped functioning or was
physically removed from the system. Check too see whether the circuit
pack is present in the slot indicated by the error. If the circuit pack is there,
then reset it with
reset board UUCSS
. If the error persists, than replace
the circuit pack.
b. Packet Gateway circuit pack has been busied out by command.
c. Packet Gateway circuit pack has not been administered for the slot in
which it is inserted.
d. This error indicates transient communication problems between the switch
and this circuit pack. This error is not service affecting and can be ignored
unless repeated failure of the Control Channel Loop-Around Test indicates
a hardware failure of the circuit pack.
e. A hardware failure on the circuit pack has been detected and reported by
the circuit pack. These errors are detected by initialization or background
tests which run on the circuit pack. The detection of one of these errors
causes the circuit pack to "lock up" and appear insane to the system See
error type 1.
The reported aux data values correspond to the following detected errors:
f. This error is reported by the circuit pack when it detects a program logic
error. This error can be ignored, but may lead to errors of other types
being reported against this circuit pack.
g. This error is reported by the circuit pack when it cannot update NPE
memory and read it back. This error type can be ignored, but may lead to
errors of other types being reported against this circuit pack.
h. A critical hardware or firmware failure has been detected on the circuit
pack. The switch resets the circuit pack upon the report of one of these
errors. If three of these errors are received in 15 minutes, a MINOR alarm
is raised on the circuit pack. Try clearing the alarm by executing the reset
board UUCSS command. The circuit pack should be replaced if this
alarm cannot be resolved.
The reported error types correspond to the following detected errors:
4352: External RAM error
4353: Internal RAM error
4355: ROM Checksum error
4357: Instruction set error