DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-343BRI-SET, ASAI-ADJ, BRI-DAT
9
50 Requested
Facility Not
Subscribed
Requested facility is implemented, but not
administered. Potential administration problem
with endpoint or adjunct. For BRI endpoints:
1. Verify the switch administration of endpoint
using either the
display station
or
display
data-module
commands.
2. If Step 1 does not resolve the problem, refer
to the endpoint’s service manual and verify
administration on the endpoint.
3. If Step 2 does not resolve the problem,
escalate to the next tier.
For ASAI adjuncts:
1. Display the Customer Optional Features
Form (administration screen) on the switch
to determine which ASAI capabilities are
turned on in the switch.
2. Verify that the adjunct is administered to
support the identical capabilities as the
switch. If there is a mismatch in the
administered capabilities, then readminister
the switch and/or the adjunct to establish a
consistent set of desired capabilities on
both the switch and the adjunct.
3. If Step 2 does not resolve the problem,
escalate to the next tier.
For Lucent adjuncts:
1. Display the Customer Optional Features
Form (administration screen) on the switch
to determine if the Lucent adjunct is set
enabled on in the switch.
2. If error type 2567 or 2568, verify the Lucent
adjunct version, and readminister if
needed.
3. If step 2 does not fix the problem, escalate
to the next tier of support
Table 9-150. ISDN-BRI CAUSE VALUES — Continued
Error
Code Test Result Description/ Recommendation